BEHIND THE RESULT
How the calculation works
Plan energy and output as in the Battery Backup tool. Equivalent runtime h = existing nominal Wh × usable fraction ÷ (schedule-average load W ÷ efficiency + battery-side idle W). Additional reserve affects sizing, not the displayed runtime.
Capacity in Wh, continuous output in W, startup behavior, and regional outlet compatibility are separate checks. Catalog entries are manufacturer specifications, not hands-on test results. They are ordered by nominal capacity, with no commission preference.
A worked example
A 60 W laptop and a 10 W lamp, each for 4 hours, use 280 Wh. With 80% usable capacity, 90% efficiency, 20% extra reserve and no idle draw, nominal capacity is 466.67 Wh. A 1,000 Wh station has about 10.29 equivalent hours at the 70 W average load, before extra reserve.
What this estimate can’t tell you
Equivalent runtime repeats the schedule-average load; it does not simulate each appliance’s on/off timing. Unknown startup values remain unknown. Even a numerical match requires manufacturer confirmation of surge duration, per-outlet limits, frequency and exact plug fit. Ordinary plug-in loads only; no medical life-support or whole-home integration.
Sources & methodology
Formulas are derived from the units shown. Read our methodology or report a correction. Sources reviewed 2026-11-01.